On this page
Signal check
What changed—and what was not tested
A combined physiotherapy pathway showed an additional functional signal, while several structural measures did not differ significantly. The study cannot isolate a Semax-only effect or justify using a consumer nasal spray for glaucoma.
[Changes in retinal light sensitivity and morphometry during surgical treatment of primary glaucoma with physiotherapeutic stimulation]. (2026)
- Measured signal
- Visual-field measurements and retinal structural parameters after surgery.
- Design
- Prospective cohort after glaucoma surgery, comparing adjunctive treatment pathways.
- Population or preparation
- 50 patients, representing 64 eyes with stage II–III primary open-angle glaucoma.
- Reported change
- A combined physiotherapy pathway showed an additional functional signal, while several structural measures did not differ significantly.
- Inference boundary
- The study cannot isolate a Semax-only effect or justify using a consumer nasal spray for glaucoma.
The experimental design
Prospective cohort after glaucoma surgery, comparing adjunctive treatment pathways.
Who or what was studied
50 patients, representing 64 eyes with stage II–III primary open-angle glaucoma.
The measurement
Visual-field measurements and retinal structural parameters after surgery. For a separate account of functional connectivity involving predefined amygdala and prefrontal regions, read Semax and Selank connectivity research. For a separate account of ulcer healing over a short treatment observation period, read Semax in an older ulcer report.
The reported finding
A combined physiotherapy pathway showed an additional functional signal, while several structural measures did not differ significantly. Both the surgery and the co-interventions matter. The comparison includes stimulation, electrophoresis and inhalation in one pathway, while the other pathway also includes Semax drops. Omitting those details would turn a package comparison into a drug-versus-placebo claim.
What the result cannot establish
The study cannot isolate a Semax-only effect or justify using a consumer nasal spray for glaucoma. Glaucoma management requires appropriate eye care. A report of adjunctive physiology after surgery is not a reason to replace pressure-lowering treatment or delay specialist follow-up. The consultation checklist can help you ask which part of this experimental result matches the preparation and goal under discussion.
A related comparison
The Semax healthy-volunteer brain imaging guide concerns a different population and endpoint. Neither a retinal measurement nor a brain scan should be generalized to an everyday focus benefit.
Evidence index
Original research and documented service details.